Artesia, CA Appliance Air Conditioning Heating Repair and Service
Artesia, CA Appliance, Air Conditioning and Heating Repair
Los Angeles Artesia, CA Appliance Repair
HOME BRANDS WE REPAIR WARRANTY PRICES AREAS WE SERVICE TESTIMONIALS CONTACT US
 
Artesia, CA Appliance Repair > Artesia, CA Stove Repair

We repair all brands/models stoves in Artesia, CA such as Sears stoves, Whirlpool stoves, GE stoves, Sunray stoves, Amana stoves and many more. (view the complete brands list we work on). We are open 24 hours a day, 7 days a week and there is no extra charge for the weekend or night appointments. Our service call is Free with the repair and all the work is guaranteed for 1 year.

800 207-3204

We provide stove repair to all Artesia, CA zip codes and surrounding cities. The following areas correspond to our Appliance service areas:

Los Angeles
Long Beach
Glendale
Santa Clarita
Beverly Hills
Temple City
Calabasas
South Pasadena
Hollywood
Torrance
San Fernando
San Gabriel
West Hollywood

El Monte
Hawthorne
Inglewood
Downey
West Covina
Lakewood
Sun Valley
Burbank
Agoura Hills
Carson
Hermosa Beach
Inglewood
Lancaster

Malibu
Manhattan Beach
Playa Del Rey
Redondo Beach
Westlake Village
Carson
Monterey Park
El Segundo
Santa Monica
South Pasadena
West Covina
Pasadena
Palmdale

View the list of our service areas.

We repair all brands stoves

Maytag
Whirlpool
GE
Thermador
Wedgewood
LG
Jenn-Air
Sub-Zero

Sears
Frigidaire
Speed Queen
Bosch
Fisher & Paykel
Hotpoint
Kenmore
Ruud

O'Keefe and Merritt
Sunray
Admiral
Samsung
Frigidare
Miele
Magic Chef
Tappan

And many more stoves that we repair in Artesia, CA brands view the full list

We have been in Appliance Repair business for eight years. For immediate Artesia, CA stove repair service call us 24/7 out our toll free number:

800 207-3204

You can also can contact us by the for your Artesia, CA stove repair. Just send us your name, a brief description of the stove problem and your contact information.

Please read these preventative and easy-to-repair tips. However if your stove problem cannot be resolved with our easy tips, consider calling us for an appointment. We will be happy to help.

Gas ranges and stoves controls

The following is a description of most of the controls used oil gas ranges.
Gas Pressure Regulator
Most gas ranges are equipped with convertible pressure regulators. The regulator is preset for 4 inches water column for use on natural gas, and may be 10 inches of water column for use on LP gas. The range regulator is not adjustable.
Caution: Never attempt to use range regulators as the sole pressure regulator for LP gas. They are secondary-type range regulators and must be used in conjunction with a high pressure range regulator at the main LP gas supply tank.
The maximum allowable supply pressure to the range regulator is 14 inches of water column. The minimum supple pressure required for checking the regulator setting is 5 inches of water column for natural gas and 11 inches of water column for LP gas.
Three types of range regulators are used. To convert a stove to a different gas, find the regulator type used and make the conversion.
Surface Range Burners
The four surface range burners are made of plated steel and aluminum. The igniter ports on the side of the range burner head must be cleaned and in alignment with the flash tube for proper homer ignition. The range burner air shutter is a spring steel self-locking type. Care should be taken during cleaning and handling to prevent changing the stove shutter setting.
Air stove shutter adjustment turn on each range burner and examines its flame. It should be blue in color and not blow away from the range burner. If not, an air shutter adjustment will be necessary. Lift or remove the main stove top. Turn on the stove burner and adjust the air shutter to obtain a flame that is blue in color and does not blow away from the range burner head.

Range Surface Burner Valves

Most ranges use either a standard or surface burner valves. Both stove types are the push-to-turn type and use a universal gas orifice.
Universal gas orifices are designed to operate with either natural or LP gas.
The range universal orifice is a combination of a fixed orifice and an adjustable orifice. The needle is fixed in a position, while the stove orifice hood adjustable. The needle has an orifice drilled through it that is sized for LP gas operation.
In order to operate the range on LP gas, the orifice hood is screwed all the way down until the tapered needle point completely blocks off the orifice in the stove hood. The LP gas rate is now set by the size of the fixed orifice through the needle and the range gas pressure.
To operate the stove burners on natural gas, the orifice hood is screwed away from the needle. Gas then flows through the fixed orifice in the needle anti through the opening between the shoulder of the needle and the edge of the orifice in the stove hood.
With this arrangement, the natural gas rate is adjustable, while the LP gas is not. To change the gas flow rate remove the needle and replace the orifice hood with one of the desired prefacing.

If you need professional assistance for your Artesia, CA stove repair needs, call us 24/7:

800 207-3204

Or send an appointment request online at To do so, please specify your name, address and a brief nature of the stove problem. Once we receive your request we will contact you as soon as possible.